{"id":2516,"date":"2023-10-17T13:22:51","date_gmt":"2023-10-17T13:22:51","guid":{"rendered":"https:\/\/cordovamcs.com\/?page_id=2516"},"modified":"2024-03-06T18:00:19","modified_gmt":"2024-03-06T18:00:19","slug":"datahawk","status":"publish","type":"page","link":"https:\/\/cordovamcs.com\/datahawk\/","title":{"rendered":"DataHawk"},"content":{"rendered":"

 <\/p>\n

Record Operational Efficiency for Regulatory Reporting<\/span><\/p>\n<\/div>

Economical Uptime and Downtime Monitoring<\/div><\/h3><\/div>
<\/div><\/div>
\"The<\/span><\/div>

Pair DataHawk with VentHawk systems, enclosed combustion units or production equipment burner systems for monitoring critical uptime and downtime.<\/p>\n<\/div>

<\/div><\/div><\/div>

Record Operational Efficiency for Regulatory Reporting<\/span><\/p>\n<\/div>

Economical Uptime and Downtime Monitoring<\/div><\/h3><\/div>
<\/div><\/div>
\"The<\/span><\/div>

Pair DataHawk with VentHawk systems, enclosed combustion units or production equipment burner systems for monitoring critical uptime and downtime.<\/p>\n<\/div>

<\/div><\/div><\/div>
<\/i><\/div>

Monitor, Record, Alert<\/h3><\/div>
<\/div>
\n

DataHawk monitors and records VentHawk and burner systems performance and alerts user if issues occur<\/p>\n<\/div>

<\/div><\/div><\/div>
<\/i><\/div>

Log Data<\/h3><\/div>
<\/div>
\n

Store 500,000 records with automatic rollover of oldest data first and data logging speed up to 1 log per second<\/p>\n<\/div>

<\/div><\/div><\/div>
<\/i><\/div>

Data Storage<\/h3><\/div>
<\/div>
\n

Store data and review later for downtime calculation<\/p>\n<\/div>

<\/div><\/div><\/div>
<\/i><\/div>

Easy Configuration<\/h3><\/div>
<\/div>
USB port to easily configure unit and retrieve data<\/div>
<\/div><\/div><\/div>
<\/i><\/div>

Automation<\/h3><\/div>
<\/div>
\n

RS232 or RS485 for data retrieval through existing automation<\/p>\n<\/div>

<\/div><\/div><\/div>
<\/div><\/div>
<\/div><\/div><\/div><\/div><\/div><\/div>
Download Brochure<\/span><\/a><\/div><\/div><\/div><\/div><\/div>

FEATURES<\/p>\n<\/div>

Features of DataHawk<\/h3><\/div>
<\/div><\/div><\/div><\/div>
<\/div><\/div><\/div><\/div>

Data Logging<\/h4><\/div>

Capable of data logging with 2 digital and 2 analog inputs, plus battery and temperature<\/p>\n<\/div><\/div><\/div>

Connectors<\/h4><\/div>

Pluggable terminal connectors<\/p>\n<\/div><\/div><\/div>

Digital<\/h4><\/div>

Digital inputs have optional one-board pull ups for contact switches<\/p>\n<\/div><\/div><\/div>

Analog<\/h4><\/div>

Analog inputs can be with 0-30V, 4-20mA or Type K thermocouples<\/p>\n<\/div><\/div><\/div>

<\/div><\/div><\/div><\/div>

Power Terminals<\/h4><\/div>

Power terminals for analog inputs to support various sensors<\/p>\n<\/div><\/div><\/div>

Configurable Options<\/h4><\/div>

Including site names, input names, aliases for digital high\/low, analog scaling<\/p>\n<\/div><\/div><\/div>

USB<\/h4><\/div>

USB flash drive used for configuration and download of data<\/p>\n<\/div><\/div><\/div>

Protected Storage<\/h4><\/div>

Redundant, CRC protected storage to ensure data integrity and prevent data loss<\/p>\n<\/div><\/div><\/div><\/div><\/div>

Specifications<\/strong><\/p>\n<\/div>

<\/div><\/div>
<\/i><\/span><\/div>
<\/i><\/span><\/div>
<\/i><\/span><\/div>
<\/i><\/span><\/div>
<\/i><\/span><\/div>
<\/i><\/span><\/div>
<\/i><\/span><\/div>
<\/i><\/span><\/div><\/div>
Enclosure<\/div>
4 x 2.8 x 1<\/div><\/div>
Power<\/div>
12vdc or 24vdc with battery backup<\/div><\/div>
2 Analog & 2 Digital Inputs<\/div>
Up to 30V<\/div><\/div>
Power\/Content Draw<\/div>
2mA(idle)\/13mA (comm port utilized)<\/div><\/div>
Digital Input Threshold<\/div>
~0.7V (transistor input)<\/div><\/div>
Analog Input Accuracy<\/div>
Larger of \u00b110mV or \u00b12%<\/div><\/div>
Board Temperature Sensor Accuracy<\/div>
\u00b14\u00b0C<\/div><\/div>
Battery Voltage Input Accuracy<\/div>
\u00b12%<\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div>

Specifications<\/strong><\/p>\n<\/div>

<\/div><\/div>
<\/i><\/span><\/div>
<\/i><\/span><\/div>
<\/i><\/span><\/div>
<\/i><\/span><\/div>
<\/i><\/span><\/div>
<\/i><\/span><\/div>
<\/i><\/span><\/div>
<\/i><\/span><\/div><\/div>
Enclosure<\/div>
4<\/div><\/div>
Power<\/div>
12vdc or 24vdc with battery backup<\/div><\/div>
2 Analog & 2 Digital Inputs<\/div>
Up to 30V<\/div><\/div>
Power\/Content Draw<\/div>
2mA(idle)\/13mA (comm port utilized)<\/div><\/div>
Digital Input Threshold<\/div>
~0.7V (transistor input)<\/div><\/div>
Analog Input Accuracy<\/div>
Larger of \u00b110mV or \u00b12%<\/div><\/div>
Board Temperature Sensor Accuracy<\/div>
\u00b14\u00b0C<\/div><\/div>
Battery Voltage Input Accuracy<\/div>
\u00b12%<\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div>
<\/div><\/div><\/div><\/div><\/p>\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":2,"featured_media":2474,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"100-width.php","meta":{"_uf_show_specific_survey":0,"_uf_disable_surveys":false,"footnotes":""},"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/cordovamcs.com\/wp-json\/wp\/v2\/pages\/2516"}],"collection":[{"href":"https:\/\/cordovamcs.com\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/cordovamcs.com\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/cordovamcs.com\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/cordovamcs.com\/wp-json\/wp\/v2\/comments?post=2516"}],"version-history":[{"count":21,"href":"https:\/\/cordovamcs.com\/wp-json\/wp\/v2\/pages\/2516\/revisions"}],"predecessor-version":[{"id":2851,"href":"https:\/\/cordovamcs.com\/wp-json\/wp\/v2\/pages\/2516\/revisions\/2851"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/cordovamcs.com\/wp-json\/wp\/v2\/media\/2474"}],"wp:attachment":[{"href":"https:\/\/cordovamcs.com\/wp-json\/wp\/v2\/media?parent=2516"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}