Record Operational Efficiency for Regulatory Reporting

Economical Uptime and Downtime Monitoring

The front of Cordova Methane Controls DataHawk device.

Pair DataHawk with VentHawk systems, enclosed combustion units or production equipment burner systems for monitoring critical uptime and downtime.

Record Operational Efficiency for Regulatory Reporting

Economical Uptime and Downtime Monitoring

The front of Cordova Methane Controls DataHawk device.

Pair DataHawk with VentHawk systems, enclosed combustion units or production equipment burner systems for monitoring critical uptime and downtime.

FEATURES

Features of DataHawk

Data Logging

Capable of data logging with 2 digital and 2 analog inputs, plus battery and temperature

Connectors

Pluggable terminal connectors

Digital

Digital inputs have optional one-board pull ups for contact switches

Analog

Analog inputs can be with 0-30V, 4-20mA or Type K thermocouples

Power Terminals

Power terminals for analog inputs to support various sensors

Configurable Options

Including site names, input names, aliases for digital high/low, analog scaling

USB

USB flash drive used for configuration and download of data

Protected Storage

Redundant, CRC protected storage to ensure data integrity and prevent data loss

Specifications

Enclosure
4 x 2.8 x 1
Power
12vdc or 24vdc with battery backup
2 Analog & 2 Digital Inputs
Up to 30V
Power/Content Draw
2mA(idle)/13mA (comm port utilized)
Digital Input Threshold
~0.7V (transistor input)
Analog Input Accuracy
Larger of ±10mV or ±2%
Board Temperature Sensor Accuracy
±4°C
Battery Voltage Input Accuracy
±2%

DataHawk FAQ

DataHawk is an economical uptime and downtime monitoring device from Cordova Methane Controls. It monitors and records the performance of VentHawk systems, enclosed combustion units and production equipment burner systems, and alerts users if issues occur. It is designed to record operational efficiency for regulatory reporting.

DataHawk collects data through 2 analog and 2 digital inputs, storing up to 500,000 records across dual 64Mb memory chips with automatic rollover. Data can be retrieved via USB or through existing automation systems using RS232 or RS485. Smart firmware prevents writes when voltage drops below 5.3V, protecting against data corruption.

Currently, the DataHawk is capable of storing 500,000 records with automatic rollover of oldest data first and data logging speed up to one log per second. Users can store data and review later for downtime calculation.

Yes, DataHawk data is protected. Redundant, CRC protected storage is utilized to ensure data integrity and to prevent possible data loss.

DataHawk supports data logging at a speed of up to 1 log per second.

DataHawk stores up to 500,000 records with automatic rollover, overwriting the oldest data first. Logging speed supports up to one record per second, making it suitable for downtime tracking and post-event analysis.

DataHawk uses dual 64Mb memory chips for redundant storage and CRC-protected writes to ensure data integrity. Smart firmware also prevents writes when voltage drops below 5.3V, guarding against corruption during power fluctuations.

Specifications

Enclosure
4
Power
12vdc or 24vdc with battery backup
2 Analog & 2 Digital Inputs
Up to 30V
Power/Content Draw
2mA(idle)/13mA (comm port utilized)
Digital Input Threshold
~0.7V (transistor input)
Analog Input Accuracy
Larger of ±10mV or ±2%
Board Temperature Sensor Accuracy
±4°C
Battery Voltage Input Accuracy
±2%